24 AWG wire: amps, diameter & uses

24 AWG wire is 0.0201" across, 0.511 mm, about 50 turns per inch wound tight. Ten turns measure 5.11 mm, the reliable way to check it; the nearest British size is SWG 25 (0.508 mm). Its copper resistance is 25.7 Ω per 1000 ft at 20 °C. Used for Ethernet (Cat 5e and Cat 6) conductors and telephone wire.

1:1 · reading this screen…
Drawing at true size…

01 · 1:1 wire gauge · coil wrap

24 AWG · bare solid copper

THIS IS:

24 AWG COPPER · NOT BUILDING WIRE · 0.51 MM COPPER

Gauge
24 AWG
bare solid copper
Breaker
n/a
not building wire
Measured
0.510 mm
0.0201"

10 turns over 5.10 mm is 0.510 mm per turn: 24 AWG (0.511 mm), SWG 25.

  • Drawn at true sizecalibrated screen

24 AWG

Solid diameter
0.0201"0.511 mm · ASTM B258 formula
Area
404 cmil0.205 mm² · nearest IEC 0.5 mm²
DC resistance, 75 °C
31.22 Ω/1000 ftcopper, from resistivity
Copper weight
1.22 lb/1000 ft

Ampacity

Table 310.16
not listedsmaller than building wire: see the chassis and craft notes

Other gauges

Nearest SWG
SWG 250.02" · 0.508 mm
IEC 60228
0.5 mm²between — and 0.5 mm²

24 AWG at a glance

Size

Solid diameter
0.0201" · 0.511 mm
Area
404 cmil · 0.205 mm²
Metric
— – 0.5 mm²
SWG nearest
25 (0.508 mm)

Electrical

Resistance 20 °C
25.67 Ω/1000 ft
Resistance 75 °C
31.22 Ω/1000 ft
As cord
not rated
Copper weight
1.22 lb/1000 ft

Measure & run

10 turns measure
5.11 mm
Turns per inch
49.7
12 V at 1 A
5 ft at 3 %

24 AWG reference 20 rows

Sort any column, print a shop sheet, download CSV. Click a row to load it in the calculator.

05 / Field guide

24 AWG
measured by the coil.

24 AWG wire is 0.0201" across, 0.511 mm, about 50 turns per inch wound tight. Ten turns measure 5.11 mm, the reliable way to check it; the nearest British size is SWG 25 (0.508 mm). Its copper resistance is 25.7 Ω per 1000 ft at 20 °C. Used for Ethernet (Cat 5e and Cat 6) conductors and telephone wire.

Between its neighbours

24 AWG has 59 % more copper than 26 AWG and 37 % less than 22 AWG. Its DC resistance is 31.22 Ω per 1000 ft at 75 °C, and 1000 ft of it carries 1.22 lb of copper.

Electronics and craft

24 AWG is used for Ethernet (Cat 5e and Cat 6) conductors and telephone wire. At 50 turns to the inch it is fine enough that a single pixel on most screens is 39 % of its width.

On the 1:1 gauge

The caliper above opens at 0.511 mm. This is finer than a screen pixel can resolve reliably, so the stage opens on the coil ruler: wind 10 turns and close the jaw on the coil.

Questions

Answered plainly.

01

How many amps can 24 AWG wire carry?

+

Table 310.16 does not rate it: 24 AWG is electronics, signal and craft wire. In practice it carries well under 1 A in bundles; check the maker’s rating.

02

What is the diameter of 24 AWG wire?

+

0.0201 inch (0.511 mm) solid.

03

What is 24 AWG in mm²?

+

0.205 mm² (404 circular mils). The IEC sizes either side are none and 0.5 mm²; replace it with 0.5 mm², not the smaller one.

04

How do I measure 24 AWG wire?

+

Wind 10 tight turns side by side and measure the coil: 5.11 mm for 24 AWG. A ruler or a screen cannot resolve a single strand this fine.

05

What is 24 AWG in SWG?

+

The nearest British Standard Wire Gauge is SWG 25 at 0.508 mm, against 0.511 mm for 24 AWG.

Browse all 20 gauges, 12 conduit sizes and 10 circuits

Every gauge in one table →